Hirata Valve Cryogenic Gate Valve Replacement: Technical Information Required for Quotation
Updated: 5 days ago
Nichiboku's industrial Insights
Introduction
Replacing an installed Hirata Valve Industry cryogenic gate valve requires identification of the original valve configuration and the actual operating conditions.
Pressure class, nominal size, body material and external appearance alone are insufficient to confirm interchangeability. Hirata Valve Industry manufactures valves according to customer specifications; consequently, two visually similar valves may differ in dimensions, internal materials, sealing construction and temperature capability. ( Hirata Cryogenic Gate Valve Replacement)

Confirmed Manufacturer Scope:
The following information is confirmed at the Hirata Valve gate-valve product-family level. It does not define the specification of an individual installed valve.
Parameter | Confirmed Manufacturer Information |
Manufacturer | Hirata Valve Industry Co., Ltd. |
Product Category | Gate valve |
Function | Full-open or full-closed flow isolation |
Throttling Service | Not intended for intermediate-opening flow regulation |
Low-Temperature Fields | Liquid hydrogen, liquid nitrogen and liquefied natural gas |
Nominal Pressure Range | 150LB to 2500LB; 10K to 63K |
Nominal Size Range | 15A to 1500A; 1/2B to 60B |
Operation Methods | Manual, pneumatic, motorized and other configurations |
Body Material Families | Carbon steel, stainless steel, cast iron and other materials |
Manufacturing Basis | Manufactured according to customer specifications |
Available size depends on pressure rating and the complete valve specification. The manufacturer’s published range does not confirm that every pressure, size, material and temperature combination is available.
Specification Boundary for the Illustrated Valve
The supplied images show an extended-bonnet cryogenic gate valve identified graphically as Class 150, 150A and SCS13A.
These values have not been verified against an official model-specific drawing, nameplate or manufacturer datasheet. They should therefore remain reference values until supported by original documentation.
The images must not be used as the sole technical basis for quotation, manufacturing or interchangeability approval.
Why Cryogenic Replacement Data Matters
Cryogenic service introduces technical requirements beyond nominal pressure and size. The valve configuration must be evaluated against the minimum operating temperature, fluid characteristics, thermal cycling and installation arrangement.
For an extended-bonnet valve, bonnet-extension dimensions and the location of the packing system may affect compatibility with existing insulation, cold-box interfaces and available operating space.
The following items can materially affect replacement suitability:
Minimum and maximum operating temperature
Design pressure and pressure-temperature rating
Exact cryogenic fluid and operating phase
Face-to-face and end-connection dimensions
Bonnet-extension length
Body, bonnet, stem, gate, seat and trim materials
Packing, gasket and sealing configuration
Flow direction and installation orientation
Manual or actuated operation
Applicable project and piping standards
A replacement should not be approved from the pressure class, nominal size and body material alone.
Technical Information Required for Quotation: Hirata Cryogenic Gate Valve Replacement
Required Information | Preferred Technical Evidence |
Manufacturer | Complete readable nameplate |
Model or Figure Number | Exact reference including all suffixes |
Serial Number | Nameplate or manufacturing record |
Original Valve Construction | Manufacturer drawing, datasheet or previous purchase specification |
Nominal Size | Drawing and nameplate |
Pressure Class | Drawing, nameplate and applicable standard |
End Connections | Flanged, welded or other construction |
Installation Dimensions | Face-to-face, flange or weld-end dimensions and installation envelope |
Bonnet Configuration | Bonnet type and complete extension dimensions |
Materials | Body, bonnet, stem, gate, seat, trim, packing and gasket |
Cryogenic Fluid | Complete fluid name, composition and operating phase |
Operating Conditions | Normal and maximum pressure and temperature |
Design Conditions | Design pressure and minimum/maximum design temperature |
Flow Information | Normal and maximum flow rate, when available |
Operation | Manual, pneumatic, electric or other actuation |
Installation | Orientation, insulation and cold-box interface |
Existing Condition | Leakage, packing problems, corrosion, erosion or operating difficulty |
Requirement | Complete valve, replacement parts or manufacturer evaluation |
Commercial Reference | Quantity, end user, direct requirement or tender, and quotation deadline |
Photographs should show the complete valve, nameplate, body markings, bonnet extension, stem, handwheel or actuator, end connections and surrounding installation.

Service Life and Replacement Assessment
The official Hirata product information does not state one fixed service-life value for every cryogenic gate-valve configuration.
Actual service life depends on the original design, cryogenic fluid, operating temperature, pressure, thermal cycles, opening frequency and maintenance history.
For an installed valve, provide its manufacturing or installation year, estimated operating period, operating cycles, repair history, observed leakage and reason for replacement. This information helps determine whether the requirement concerns normal service-life replacement, process-related damage or changed operating conditions.
Manufacturer Verification and Japan Sourcing
Once sufficient documentation is available, Nichiboku can coordinate Japan-side identification and current supply-feasibility review.
Manufacturer confirmation may be required to establish whether the original configuration remains available or must be reviewed as a new made-to-order requirement. Submission of technical information does not automatically confirm availability or interchangeability.
Review Hirata Valve Industry products through Nichiboku:
Submit the drawing, nameplate photographs and technical specification through the Nichiboku RFQ form:
Japanese Industrial Products
Explore Nichiboku’s virtual catalogue of Japanese industrial equipment, valves and replacement components:
.png)