top of page

Hirata Valve Cryogenic Gate Valve Replacement: Technical Information Required for Quotation

Sep 8
3 min read

Updated: 5 days ago

Nichiboku's industrial Insights

Introduction

Replacing an installed Hirata Valve Industry cryogenic gate valve requires identification of the original valve configuration and the actual operating conditions.

Pressure class, nominal size, body material and external appearance alone are insufficient to confirm interchangeability. Hirata Valve Industry manufactures valves according to customer specifications; consequently, two visually similar valves may differ in dimensions, internal materials, sealing construction and temperature capability. Hirata Cryogenic Gate Valve Replacement)


Cryogenic gate valve product shot with Hirata Valve Industry logo, specs, and extended bonnet type text on gray background.
Hirata Valve Industry's cryogenic gate valve featuring an extended bonnet design, Class 150 pressure, nominal size 150A, crafted from durable SCS13A material.

Confirmed Manufacturer Scope:

The following information is confirmed at the Hirata Valve gate-valve product-family level. It does not define the specification of an individual installed valve.

Parameter

Confirmed Manufacturer Information

Manufacturer

Hirata Valve Industry Co., Ltd.

Product Category

Gate valve

Function

Full-open or full-closed flow isolation

Throttling Service

Not intended for intermediate-opening flow regulation

Low-Temperature Fields

Liquid hydrogen, liquid nitrogen and liquefied natural gas

Nominal Pressure Range

150LB to 2500LB; 10K to 63K

Nominal Size Range

15A to 1500A; 1/2B to 60B

Operation Methods

Manual, pneumatic, motorized and other configurations

Body Material Families

Carbon steel, stainless steel, cast iron and other materials

Manufacturing Basis

Manufactured according to customer specifications

Available size depends on pressure rating and the complete valve specification. The manufacturer’s published range does not confirm that every pressure, size, material and temperature combination is available.

Specification Boundary for the Illustrated Valve

The supplied images show an extended-bonnet cryogenic gate valve identified graphically as Class 150, 150A and SCS13A.

These values have not been verified against an official model-specific drawing, nameplate or manufacturer datasheet. They should therefore remain reference values until supported by original documentation.

The images must not be used as the sole technical basis for quotation, manufacturing or interchangeability approval.

Why Cryogenic Replacement Data Matters

Cryogenic service introduces technical requirements beyond nominal pressure and size. The valve configuration must be evaluated against the minimum operating temperature, fluid characteristics, thermal cycling and installation arrangement.

For an extended-bonnet valve, bonnet-extension dimensions and the location of the packing system may affect compatibility with existing insulation, cold-box interfaces and available operating space.

The following items can materially affect replacement suitability:

  • Minimum and maximum operating temperature

  • Design pressure and pressure-temperature rating

  • Exact cryogenic fluid and operating phase

  • Face-to-face and end-connection dimensions

  • Bonnet-extension length

  • Body, bonnet, stem, gate, seat and trim materials

  • Packing, gasket and sealing configuration

  • Flow direction and installation orientation

  • Manual or actuated operation

  • Applicable project and piping standards

A replacement should not be approved from the pressure class, nominal size and body material alone.

Technical Information Required for Quotation:  Hirata Cryogenic Gate Valve Replacement

Required Information

Preferred Technical Evidence

Manufacturer

Complete readable nameplate

Model or Figure Number

Exact reference including all suffixes

Serial Number

Nameplate or manufacturing record

Original Valve Construction

Manufacturer drawing, datasheet or previous purchase specification

Nominal Size

Drawing and nameplate

Pressure Class

Drawing, nameplate and applicable standard

End Connections

Flanged, welded or other construction

Installation Dimensions

Face-to-face, flange or weld-end dimensions and installation envelope

Bonnet Configuration

Bonnet type and complete extension dimensions

Materials

Body, bonnet, stem, gate, seat, trim, packing and gasket

Cryogenic Fluid

Complete fluid name, composition and operating phase

Operating Conditions

Normal and maximum pressure and temperature

Design Conditions

Design pressure and minimum/maximum design temperature

Flow Information

Normal and maximum flow rate, when available

Operation

Manual, pneumatic, electric or other actuation

Installation

Orientation, insulation and cold-box interface

Existing Condition

Leakage, packing problems, corrosion, erosion or operating difficulty

Requirement

Complete valve, replacement parts or manufacturer evaluation

Commercial Reference

Quantity, end user, direct requirement or tender, and quotation deadline

Photographs should show the complete valve, nameplate, body markings, bonnet extension, stem, handwheel or actuator, end connections and surrounding installation.

Cryogenic gate valve infographic with front, right, left, rear views; Hirata Valve Industry logo and specs on a white grid background.
360-Degree View of Hirata Valve Industry's Extended-Bonnet Cryogenic Gate Valve: Showcasing External Front, Rear, and Side Profiles for Series 150 in Body Material SCS13A.

Service Life and Replacement Assessment

The official Hirata product information does not state one fixed service-life value for every cryogenic gate-valve configuration.

Actual service life depends on the original design, cryogenic fluid, operating temperature, pressure, thermal cycles, opening frequency and maintenance history.

For an installed valve, provide its manufacturing or installation year, estimated operating period, operating cycles, repair history, observed leakage and reason for replacement. This information helps determine whether the requirement concerns normal service-life replacement, process-related damage or changed operating conditions.

Manufacturer Verification and Japan Sourcing

Once sufficient documentation is available, Nichiboku can coordinate Japan-side identification and current supply-feasibility review.

Manufacturer confirmation may be required to establish whether the original configuration remains available or must be reviewed as a new made-to-order requirement. Submission of technical information does not automatically confirm availability or interchangeability.

Review Hirata Valve Industry products through Nichiboku:

Submit the drawing, nameplate photographs and technical specification through the Nichiboku RFQ form:

Japanese Industrial Products

Explore Nichiboku’s virtual catalogue of Japanese industrial equipment, valves and replacement components:


Comments