top of page

Meiyo Electric R-96 Low-Temperature Platinum Resistance Bulb

Sep 11
3 min read

Updated: 5 days ago

Nichiboku's industrial Insights

Introduction

Temperature measurement in marine machinery requires the sensor configuration to match the monitored medium, operating range, installation arrangement and connected instrumentation.

The Meiyo Electric R-96 is a terminal-box-type Pt100 platinum resistance bulb for measuring and monitoring temperatures in ship-engine systems. Confirmed applications include cooling water, lubricating oil, fuel oil, seawater and bearing systems. The manufacturer also identifies outside-air temperature measurement in its product description. (Meiyo Electric R-96 Platinum Resistance Bulb)


Silver industrial temperature sensor with perforated probe on white background, labeled MEIYO ELECTRIC, Temperature Sensor, Model R-96
Meiyo Electric R-96 low-temperature platinum resistance bulb featuring a durable terminal box and protective tube, designed for precision temperature sensing.

Response Performance for Marine Temperature Measurement

Meiyo Electric identifies response speed as an important performance requirement for low-temperature measurement.

The manufacturer states that the R-96 incorporates a resistance element with low thermal capacity and a construction designed to improve heat conduction. It also indicates that double-protection-tube construction can maintain characteristics comparable to single-protection-tube types.

This response behavior is relevant when monitoring temperature changes in lubricating oil, cooling water, bearings and other machinery conditions.

Confirmed Manufacturer Specifications: Meiyo Electric R-96 Platinum Resistance Bulb

The following values are taken from the official Meiyo Electric R-96 product page.

Parameter

Confirmed Manufacturer Specification

Manufacturer

Meiyo Electric Co., Ltd.

Product Category

Temperature sensor — platinum resistance bulb for low-temperature use

Model

R-96

Nominal Resistance at 0°C

Pt100 Ω

Published Current Value

2 mA

Class

Class B

Listed Operating Temperature Ranges

−200 to 100°C; 0 to 350°C; 0 to 500°C

Standard Protection-Tube Material

SUS304

Connection

3 Terminal

Standard Protection Tube

Single

Terminal Type

Terminal box

Standard Length L

150, 200 or 300 mm

Outside Diameter φD

8, 10, 12 or 15 mm

Attached Plug

No standard value stated

Listed Applications

CFW, LO, FO, SW and bearing systems

In the manufacturer’s description, these applications correspond to cooling water, lubricating oil, fuel oil, seawater and bearing-temperature measurement.

Specification Boundary and Replacement Selection

The temperature ranges, lengths and tube diameters shown above are published options. The manufacturer’s online information does not confirm that every possible combination is available or appropriate for every installation.

The standard specification identifies a single protection tube, while the product description also discusses the performance of double-protection-tube construction. The exact construction must therefore be confirmed from the applicable drawing or manufacturer quotation.

The following details are not established by the general online specification:

  • Exact process connection or mounting arrangement

  • Available combinations of temperature range, length and diameter

  • Required insertion depth

  • Complete installation dimensions

  • Terminal-box cable entry

  • Permissible process pressure

  • Installation-specific environmental requirements

Another sensor should not be treated as interchangeable only because it uses a Pt100 element, Class B accuracy or three-terminal wiring. The complete construction, dimensions, electrical characteristics and operating conditions require verification.

The accompanying product images are illustrative external views. They are not manufacturer drawings and must not be used to determine dimensions, materials, connections or installation compatibility.

Silver temperature sensor with perforated probe shown in front, side, rear, and left views; text reads MEIYO ELECTRIC, MODEL R-96.
Four-angle views of the Meiyo Electric Co., Ltd. R-96 model showcase its design and features as a low-temperature platinum resistance bulb for temperature sensing.

Technical Information Required for Quotation

Required Information

Technical Evidence or Value to Provide

Manufacturer and Model

Meiyo Electric R-96 identification and readable nameplate

Original Documentation

Manufacturer drawing, datasheet or previous purchase specification

Application

Cooling water, lubricating oil, fuel oil, seawater, bearing, outside air or other service

Temperature Conditions

Normal, minimum and maximum measurement temperatures

Electrical Specification

Pt100 requirement, class, current value, wiring and connected instrument

Protection Tube

Material, single or double construction, outside diameter and length

Installation Details

Process connection, insertion depth, mounting dimensions, orientation and available clearance

Terminal Box

Cable entry, terminal arrangement and existing wiring details

Operating Environment

Process pressure, vibration, moisture and corrosion exposure where applicable

Existing Condition

Calibration deviation, damaged tube, corrosion, terminal deterioration or wiring failure

Procurement Information

Required quantity, end user or plant, direct supply or tender, destination and quotation deadline

Marine Delivery Information

Vessel name, IMO number, delivery port and port-stay window when applicable

When the original drawing is unavailable, provide photographs of the complete sensor, nameplate, terminal box, protection tube, process connection and installation point.

Submit technical documents through the Nichiboku RFQ form.

Service Life and Condition Assessment

The official R-96 product information does not state a fixed service-life value.

Continued suitability should be evaluated from calibration results, resistance stability, thermal cycling, vibration exposure, protection-tube condition, terminal integrity, wiring condition and maintenance history. Installation age alone does not establish remaining service life.

International Sourcing from Japan

Nichiboku supports marine operators, industrial end users, maintenance departments, EPC contractors and procurement teams requiring identified Meiyo Electric temperature sensors from Japan.

Quotation and supply feasibility remain subject to confirmation of the complete R-96 configuration, manufacturer review and current availability.



Comments