Major Threats to Long-Term Thermocouple Accuracy in Industrial Applications
- Luis Alberto Fing

- Dec 15, 2025
- 3 min read
Welcome to Nichiboku's industrial Blog
Introduction
Thermocouples are widely used in industrial temperature measurement due to their robustness, wide operating range, and fast response. However, the major threats to long-term thermocouple accuracy remain a critical concern in harsh industrial environments. One of the most significant threats to long-term thermocouple accuracy is thermocouple accuracy drift, a failure mode that often goes unnoticed because sensor output may appear stable while becoming progressively inaccurate.
This article explains the major threats to long-term thermocouple accuracy, the mechanisms behind decalibration, and why understanding these long-term accuracy risks is essential for reliable industrial process control.

Understanding Thermocouple Accuracy Drift: Major Threats to Long-Term Thermocouple Accuracy
Thermocouple accuracy drift—also known as decalibration—is defined as the deviation of a thermocouple’s voltage–temperature relationship from its standard reference curve. This deviation is caused by irreversible changes in the chemical composition or microstructure of the thermoelement materials.
Unlike sudden sensor failure, decalibration develops gradually, making it particularly dangerous in continuous industrial processes.
Metallurgical and Chemical Deterioration: The Primary Cause of Drift
High-Temperature Oxidation and Evaporation
Prolonged exposure to oxygen at elevated temperatures causes oxidation of thermocouple alloys. This alters the bulk material composition and significantly changes thermoelectric properties, leading to measurable voltage drift over time.
Contamination and Corrosion
Thermocouple conductors are vulnerable to contamination from moisture, dirt, and chemical vapors. In petrochemical environments, corrosive gases such as hydrogen sulfide (H₂S) can aggressively attack base-metal thermocouples, accelerating metallurgical degradation. Metal vapors may also penetrate protective sheaths and contaminate the thermoelement wires, permanently shifting calibration.
Diffusion Effects and Thermal Aging
Long-term exposure to high temperatures accelerates atomic diffusion within thermocouple materials. Atoms migrate between conductors or react with surrounding insulation, causing gradual microstructural changes that permanently alter the Seebeck coefficient and reduce measurement accuracy.
Chemical Reactions with Insulation Materials
Even materials typically considered inert can become reactive under extreme conditions. Alumina (Al₂O₃) insulation may decompose in reducing atmospheres at very high temperatures, releasing free aluminum. This aluminum can react with noble metals such as platinum, forming intermetallic compounds with lower melting points, leading to premature sensor failure.
Mechanical and Electrical Stress Factors Affecting Accuracy
Mechanical Stress and Cold Working
Improper handling, excessive bending, vibration, mechanical shock, and severe thermal cycling introduce internal stresses in thermocouple wires. These stresses change the conductor structure, causing deviation from standardized thermoelectric characteristics and resulting in decalibration.
Thermal Cycling Effects
Repeated heating and cooling accelerate metal fatigue and promote microstructural changes. Over time, this leads to EMF drift, slower response, and inconsistent readings.
Reference Junction (Cold Junction) Errors
Thermocouples measure temperature differences, not absolute temperature. If the reference junction temperature is not properly compensated—especially when it deviates from ambient conditions—significant measurement errors can occur.
Ground Loops and Electrical Interference
Multiple grounding points can create ground loops, allowing unwanted current flow. This introduces electromagnetic interference (EMI), voltage offsets, and signal noise that may mimic or amplify apparent thermocouple accuracy drift.
Why Long-Term Accuracy Matters in Industrial Processes
Thermocouple decalibration can introduce errors of 10–20°F (approximately 5–11°C) or more. Because readings often remain stable, these errors may persist undetected, increasing risks related to process control instability, product quality deviations, regulatory compliance issues, and equipment safety.

Best Practices to Minimize Thermocouple Accuracy Drift
Select thermocouple types appropriate for the operating temperature and atmosphere
Use high-quality protective sheaths and insulation materials
Minimize unnecessary thermal cycling
Ensure proper grounding and shielding
Implement regular calibration or planned replacement schedules
Nichiboku Worldwide Supply Support
Nichiboku Ltd. provides global supply support for Japanese industrial products, ensuring reliable distribution and after-sales assistance worldwide.
➡️ Get global supply support
➡️ Inquire about international shipping and product availability
➡️ Partner with Nichiboku for worldwide industrial solutions
.png)



Comments