top of page

Taisei Kogyo Heat Exchanger FCF – Compact Oil Cooler for Industrial Applications

Welcome to Nichiboku's industrial Blog

Introduction

Efficient cooling is critical for maintaining the performance and longevity of industrial machinery. The Taisei Kogyo Heat Exchanger FCF model is engineered to deliver reliable oil cooling, offering high efficiency in a compact shell and tube design. This robust solution is widely adopted in hydraulic and lubrication systems, ensuring stable temperature control even in demanding industrial environments.


Blue oil cooler labeled "Taisei Kogyo Heat Exchangers, Model: FCF" on a teal background. Vertical Japanese text on the left side.
Taisei Kogyo Heat Exchanger FCF – A Compact Oil Cooler Designed for Efficient Temperature Control in Industrial Machinery.

Key Features of the Taisei Kogyo Heat Exchanger FCF

Compact High-Efficiency Cooling

The FCF heat exchanger uses φ9 low-fin tubes to maximize heat transfer performance. This allows for smaller unit sizes without compromising cooling efficiency.

Fixed Tube Sheet Structure

A simple, durable, and cost-effective design that ensures long service life and easy maintenance.

Flexible Flow Options

Available in three flow classifications to meet diverse application requirements:

  • 0 – High Flow (Large)

  • 1 – Normal Flow

  • 2 – Low Flow (Small)

Easy Installation and Maintenance

  • Adjustable U-bolt base for flexible mounting

  • Customizable flow direction

  • Easy cleaning of the tube side — ideal for environments where water tends to be dirty

Technical Specifications of the Taisei Kogyo Heat Exchanger FCF

Item

Standard Spec.

Option

Type

Fixed tube sheet

-

Maximum working pressure

Shell side: 1.0 MPa  Tube side: 1.0 MPa

-

Corresponding fluid

Shell side: Mineral oil  Tube side: Freshwater

Shell side: Water glycol oil, Fatty ester oil

Cooling tube

φ9 low-finned tube  Material: Phosphorus deoxidized copper

-

Heat transfer area

0.15 – 10 m²

-

Tie-in

Shell side: Rc threaded type  Tube side: Rc threaded type

-

Model Number Configuration

Section

Code

Description

Fluid Type

-

Mineral oil


G

Water glycol oil


Other

Fatty ester oil

Oil Quantity Classification

0

Large


1

Normal


2

Small

Size (Heat Transfer Area & Shell Diameter)

003

0.15 m² / φ63.5 mm


006

0.3 m² / φ76.3 mm


008

0.4 m² / φ76.3 mm


114

0.7 m² / φ76.3 mm (65A)


122

1.1 m²


226

1.3 m² / φ114.3 mm


234

1.7 m²


242

2.1 m² / φ114.3 mm (100A)


256

2.8 m²


270

3.5 m²


350

2.5 m²


370

3.5 m²


390

4.5 m²


311

5.5 m² / φ139.8 mm (125A)


313

6.5 m²


314

7.0 m²


316

8.0 m²


411

5.5 m²


414

7.0 m²


416

8.0 m² / φ165.2 mm (150A)


418

9.0 m²


420

10.0 m²

Example: FCF-003-1 → Model 003 with normal flow classification.

Applications of the Taisei Kogyo Heat Exchanger FCF

  • General industrial machinery cooling

  • Hydraulic systems requiring precise temperature control

  • Lubrication systems in harsh environments

  • Situations where frequent cleaning of the water side is necessary

The Taisei Kogyo Heat Exchanger FCF model is the preferred choice for industrial buyers seeking a balance of performance, durability, and versatility.

Why Choose the Taisei Kogyo Heat Exchanger FCF Oil Cooler?

With its compact yet powerful design, wide flow range, and compatibility with multiple fluids, the FCF heat exchanger is a reliable solution for maintaining stable machinery performance. Its flexibility and robust structure make it an excellent fit for a variety of industries.


Downloadable Resources

Resource

Link

PDF Drawing

CAD Drawing

Catalogue

Instruction Manual

Spare Parts List

Catalogue 2

Copyright & Disclaimer – Taisei Kogyo Co., Ltd. Download Material